SAFETY DATA SHEET
Tiponphalt
(High Performance Cold Applied Instant Road Repair)
Date: 01/01/2024
SECTION 1: Identification of the substance/mixture and of the company/undertaking
Product identifiers
Product name: Tiponphalt
Relevant identified uses of the substance or mixture and uses advised against
Identified uses: Pothole repair (cold applied)
Details of the supplier of the safety data sheet
Manufacturer / Supplier: Dream Home Innovation FZE
Address: SRTIP Free Zone, Sharjah, UAE
Telephone: +971564305251
Website: www.etihadsouq.ae
Email: [email protected]
SECTION 2: HAZARDS IDENTIFICATION
Classification (EC 1272/2008)
- Human health: Acute Tox. 4 – H312; Acute Tox. 4 – H332; Asp. Tox. 1 – H304
- Environment: Aquatic Chronic 3 – H412
- Physical and Chemical Hazards: Not classified
Classification (1999/45/EEC):
Xn; R20/21, R65. R52/53
Hazard statements:
- Harmful to aquatic life with long lasting effects
- Keep out of reach of children
- Keep away from heat, sparks, open flames
- Do not apply on open flames or ignition sources
- Do not breathe vapour or spray
- Use only outdoors or in a well-ventilated area
- Protect from sunlight; do not expose to temperatures >50ºC
- Dispose of contents/container in accordance with local regulations
SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS
Substance | CAS No. | EC No. | Concentration |
---|---|---|---|
Asphalt | 8052-42-4 | 232-490-9 | 3 – 5% |
Xylene | 1330-20-7 | 215-535-7 | 10 – 20% |
Aromatic Hydrocarbons | 64742-95-6 | 265-199-0 | 5 – 15% |
Other ingredients | NA | [-] | 80 – 100% |
SECTION 4: FIRST AID MEASURES
- Inhalation: Move to fresh air. Seek medical attention if discomfort continues
- Eyes: Rinse immediately with water for at least 15 minutes. Get medical attention
- Skin: Remove contaminated clothing and wash with soap and water
- Ingestion: Rinse mouth, give water. Monitor and seek medical advice if symptoms arise
SECTION 5: FIRE FIGHTING MEASURES
- Extinguishing media: Foam, dry chemical, CO₂ (avoid water jets)
- Special hazards: Combustion may produce CO, CO₂, and other organic vapours
- Firefighting: Use self-contained breathing apparatus. Cool containers with water spray
SECTION 6: ACCIDENTAL RELEASE MEASURES
- Personal precautions: Wear PPE. Avoid vapour inhalation. Remove ignition sources
- Environmental: Prevent from entering watercourses or soil
- Clean-up: Recover material and place in suitable containers for disposal
SECTION 7: HANDLING AND STORAGE
- Handling: Avoid contact with skin/eyes; no eating, drinking, or smoking
- Storage: Store in cool, dry, well-ventilated area away from ignition sources
SECTION 8: EXPOSURE CONTROLS/PERSONAL PROTECTION
Component | TWA (8hr) | STEL (15min) |
---|---|---|
Asphalt (fume) | 5 mg/m³ | 10 mg/m³ |
Xylene | 100 ppm | – |
PPE Requirements:
- Eyes: Goggles (EN 166)
- Hands: Heat/chemical-resistant gloves (EN 374)
- Clothing: Impervious garments
- Respiratory: Type A filters or air-supplied respirators if needed
SECTION 9: PHYSICAL AND CHEMICAL PROPERTIES
- Appearance: Black solid
- Odour: Characteristic
- Relative density: 2.1 – 2.5
- Water solubility: Immiscible
- pH: Not applicable
SECTION 10: STABILITY AND REACTIVITY
- Stability: Stable under recommended conditions
- Conditions to avoid: Heat, flames, moisture
- Incompatibility: Strong oxidizers, acids
- Decomposition: CO, CO₂, organic vapours
SECTION 11: TOXICOLOGICAL INFORMATION
- Inhalation: May cause mild respiratory irritation
- Skin: Repeated exposure may cause dryness/cracking
- Eyes: May cause transient irritation
SECTION 12: ECOLOGICAL INFORMATION
- Toxicity: Not classified as hazardous but may affect aquatic life if spilled in large quantities
- Persistence & degradability: No data
- Bioaccumulation: No data
SECTION 13: DISPOSAL CONSIDERATIONS
- Dispose of product and container per local authority requirements
SECTION 14: TRANSPORT INFORMATION
Not classified as dangerous goods under transport regulations (ADR, RID, IMDG, IATA)
SECTION 15: REGULATORY INFORMATION
- Complies with REACH Regulation (EC) No. 1907/2006
- Also subject to:
- Health & Safety at Work Act 1974
- COSHH Regulations 2002
- Environmental Protection Act 1990
- Hazardous Waste Regulations 2005
SECTION 16: OTHER INFORMATION
Prepared by: QA/QC Department, Petrozo Energy
Contact:
Phone: +971 564305251
Email: [email protected]
Disclaimer: The information provided is believed to be correct as of the date hereof. It is intended only as a guide and does not constitute a guarantee. Users must determine suitability for their application and ensure compliance with local regulations.